Welcome to your new Interacoustics Callisto. In this video, we will guide you through what's included in the box and how to connect your device so you're ready to get started quickly and confidently.

 

Unboxing

Start by opening the Callisto carrying case. Inside, you will find all the components you need and your device's calibration folder. You can store this calibration folder inside the carry case.

Next, remove all the components from the case and keep hold of any packaging as this may be needed when repacking the device for annual calibration. Inside the box, you will find the following hardware:

  • DD65 circumaural headphones
  • A B71 bone conductor
  • Patient response button
  • An SP70 loudspeaker
  • The loudspeaker splitter cable
  • The real ear measurement headset
  • The tester headset for monitoring the patient
  • The main Callisto base unit
  • And the USB cable, which also supplies power to the device

 

Connecting the system

Now you have confirmed all the required components, you are ready to connect the system. Start by placing the Callisto base unit upright in its stand and place on the desk. We will plug the components in order from bottom to the top of the device.

 

Patient response button

Take your patient response button and plug the jack connection into the port labeled 'Pat. Resp.'.

 

DD65 headphones

Next, plug the DD65 headphone jacks into the color-coded left and right ports on the Callisto unit.

 

Bone conductor

The bone conductor transducer is color-coded green. Plug the jack connection into the green port labeled 'Bone'.

 

SP70 loudspeaker

To connect your SP70 loudspeaker, start by plugging the yellow splitter cable jack into the free field port labeled 'FF'. Take the other end of the splitter cable and connect the red connector to the back of the loudspeaker.

 

Tester headset

The tester headset has two connectors. The light green being used for audio monitoring and the pink connector being the headset microphone. Connect these jacks to their respective light green and pink ports on the Callisto unit.

 

REM headset

The REM headset uses red and blue multi-pinned plugs. These plugs need to be aligned carefully and pushed into their matching-colored port on the device. Small arrows on the plugs are used to help align these correctly into the Callisto unit.

 

USB cable

Finally, connect the USB cable to the very bottom port of the Callisto. This USB will provide both power and data transfer to the device.

Everything is now connected. Take a moment to double-check that all the ports are securely connected and the cables are well organized. To turn on the device, connect the other end of the USB cable to your PC. A green light will illuminate on the device to show that it is now receiving power. Your Interacoustics Callisto is now connected and ready to use.

Available Training

AC440 Protocol Setup

There are many different demands and wishes regarding how an audiometer should both function and appear depending on the specific situation and national standards. One of the greatest advantages of the AC440 module is the flexibility, enabling you to tailor the system according to your specific preferences in the so-called “test protocols”. This article describes basic functionality on how to work with the AC440 Protocols.

Interacoustics2026-10-02

Acceptable Noise Level (ANL) Test

Learn how to perform the acceptable noise level (ANL) test with the CallistoTM device.

Interacoustics2026-10-02

Adult Hearing Aid Verification

Learn how to verifiy hearing aids in adults with the CallistoTM device, using real ear measurements (REM).

Interacoustics2026-10-02

Basic Audiometry

Learn how to do basic audiometry with the CallistoTM device.

Interacoustics2026-10-02

Binaural Real Ear Measurements

Learn how to perform binaural real ear measurements (REM) with the CallistoTM.

Interacoustics2026-10-02

BKB-SIN speech-in-noise test

In this quick guide, you will learn how to use the BKB-SIN speech-in-noise test provided with the Interacoustics CallistoTM audiometer. Read more.

Interacoustics2026-10-02

How to perform CROS and BiCROS fitting

Learn how to fit CROS and BiCROS hearing aids with the CallistoTM device.

Interacoustics2026-10-02

Customized Printout Setup

Customized Printout Setup

Interacoustics2026-10-02

How to perform FM transparency verification

In this CallistoTM quick guide, you'll learn how to perform FM transparency verification. Read more.

Interacoustics2026-10-02

How to perform frequency lowering verification

In this CallistoTM quick guide, you'll learn how to determine if you should apply frequency lowering and how to verify the frequency lowering feature.

Interacoustics2026-10-02

How to Verify Directional Hearing Aids

Learn how to verify directional hearing aids with the Callisto™ system, using real ear measurements (REM).

Interacoustics2026-10-02

Verifying Ear Level FM Systems

Verifying Ear Level FM Systems

Interacoustics2026-10-02

Print Reports

Learn how to create customized print templates for the Callisto™, which can be linked to individual protocols for quick printing.

Interacoustics2026-10-02

QuickSIN Test

Learn how to perform the quick speech in noise (QuickSIN) test with the CallistoTM device.

Interacoustics2026-10-02

Real-Ear-to-Coupler Difference

Learn how to measure the real-ear-to-coupler difference (RECD) with the CallistoTM device.

Interacoustics2026-10-02

Speech in Noise (SIN) Test

Learn how to perform the speech in noise (SIN) test with the CallistoTM device.

Interacoustics2026-10-02
Unboxing Callisto: How to set up and install your Callisto | Interacoustics